Gusset Plates (G-Series & GP-Series)

Punched Or Unpunched Gusset Plates

Gusset plates for easier and faster attachments of X-Bracing or roof framing

Quick Actions:

G-Series™ Punched gusset plates

G-Series™ Punched gusset plates are multipurpose connectors used in a variety of framing connections including roof framing, header framing and shear wall applications. Adapts to varying construction tolerances and to multiple configurations.

  • Multihole shapes for proper fastening to achieve desired performance criteria
  • Eliminates angled cutting
  • Mill-certified 50 ksi steel

Product Data & Ordering Information

Gauge:  43mils (18 ga)
Design Thickness: 0.0451 inches (1.146mm)

Gauge: 54mils (16 ga)
Design Thickness: 0.0566 inches (1.438mm)

Gauge: 68mils (14 ga)
Design Thickness: 0.0713 inches (1.811mm)

Material: G90 (Z275) hot-dipped galvanized coating
                 14 & 16 gauge Mill-certified SS Grade 50 ksi (340 MPa)
                 18 gauge Mill-certified SS Grade 33 ksi (230 MPa)


GP-Series™ UNPunched, custom size Gusset Plate

Custom size, unpunched Gusset Plates are used in conjunction with X-bracing in load-bearing shear wall assemblies to resist racking under wind and seismic loads.

Gusset Plates and diagonal tension strapping components are used in combination to provide shear wall (racking restraint) for light-gauge load-bearing framing under wind and seismic loads. They are normally installed on both sides of the wall directly over the framing members and are easily covered with facing materials.

  • Provides racking restraint
  • Used in shear wall assemblies
  • Resist uplift and shear forces

CAUTION: Racking loads are first transferred to the roof or floor decking and then to the shear walls (X-bracing or Flat Strapping). The X-bracing then relies on a proper anchorage to the foundation to resist uplift and shear forces. In order for the system to function properly, the load path from the roof or floor deck to the shear walls to the foundation must be complete. This normally requires additional bracing, blocking, track and rim splices, drag struts, uplift anchors and heavy-duty foundations.

Unpunched Gusset Plates are also used to facilitate connections between chord members for in-plane framing.

Gusset Plates and diagonal tension strapping components are used in conjunction with X-bracing in load-bearing shear wall assemblies to resist racking under wind and seismic loads. They are normally installed on both sides of the wall directly over the framing members and are easily covered with facing materials.

  • Provides racking restraint
  • Used in shear wall assemblies
  • Resist uplift and shear forces